GAUGE: Clock OAT Volts Digital
Gauge v1.6.001 - Current Version 12th Feb 2024

Features:
1) Digital Clock
2) Digital Timer
3) OAT (Outside Ambient Temperature) ºC or ºF
4) Volts
5) 5 different backlights [S6]
6) Local and Zulu time From Sim
7) Local and Zulu time from PC
8) Mini Menu
9) Optional colour displays
10) Optional side buttons
11) Optional glass reflection
12) Mini menu
13) Panel lighting
14) Brightness control (Physical FIP)

Aircraft Compatibility:
Simulator: Fully Compatible
3rd Party: Fully Compatible
Fully Compatible
Fully Compatible

Buttons & Dials Summary:
[S1] Toggle Clock/Timer/LongPress toggle Timer Digits HH:MM or MM:SS:
[S2] Change time to come from SIM:
[S3] Change time to come from PC:
[S4] Change time to GMT/UTC:
[S5] Change time to Local time:
[S6] Cycle Backlight Colours/Reset Timer:
[L Dial] Function -/Function + Toggle OAT/Volts and Timer Adjustment:
[R Dial] Menu Previous Function/Menu Next Function:

About Clock OAT Volts Digital:
Digital Clock with timer function OAT and Volts Display.    
 
Unfortunately stop and start variables are not available, so timer can be reset to "00:00:00" or fast forwarded and rewound, but can't be paused as the internal clock is always ticking. All I can do it provide an offset to the increasing "runtime". Saying that the timer works well and I don't miss a start/stop option.

The Main Gauge:
Has two main functions, toggled by pressing the [S1] button.
 
1) Digital Clock:
Shows the current date on 5 different colour backlights.
 
Output time can be one of 4 different combinations:
     1) SIM time - GMT
     2) SIM time - Local
     3) PC time - GMT
     4) PC time - Local
 
2) Digital Timer.
Time can be rewound or fast forwarded in steps of 1 minute or set to "00:00:00", but is always running.
 
There is a green LED on the main display to identify if TIMER or CLOCK is active.

The Sidebar:
Contains information on your selected time settings and button labels, which change depending if clock or timer is selected.
 
If the blanking plate is used instead of the sidebar, then colour of the plate can now be changed by editing variable [FG_GLOBAL_BLANKING_COLOUR] in SPAD.neXt data monitor.

Buttons & Dials Details:
[S1] Clock & Timer Function:
Press to toggle between the clock and timer function.
 
[S2] Simulator time:
Press to set time to use time from simulator.
 
[S3] PC time:
Press to use time from PC.
 
[S4] GMT:
Press to set time zone to GMT/UTC.
 
[S5] Local time:
Press to set time to local time.
 
[S6] - Clock Mode - Backlight Colour:
When in clock mode press to toggle through the 5 different second hand colours.
     0 = Grey LCD
     1 = Blue
     2 = Orange
     3 = Green
     4 = Plain White
 
[S6] - Timer Mode - Reset timer to "00:00:00":
When in timer mode press to reset the timer to "00:00:00" and starts running from "00:00:00".
 
[L Dial] Menu Value Down/Up + Fast Forward/Rewind timer:
In Mini Menu left dials is used to increase or decrease the function of the selected menu option.
In Timer mode left dial counter clockwise re-winds the timer and clockwise fast forwards the timer.
In Clock mode left dial toggles between OAT and Volts display.
 
[R Dial] Menu Left/Right:
Used to activate the Mini Menu and scroll between the various menu options.

The Mini Menu:
(Activated with [R Dial])
 
Version & Info:
Turn left dial clockwise to turn on and counter clockwise to turn off current version number and other useful links.
 
Side Buttons:
Turn left dial clockwise to turn on and counter clockwise to turn off side buttons.
 
Time Source:
Turn left dial clockwise or counter clockwise to toggle time source between SIM & PC.
 
Time Zone:
Turn left dial clockwise or counter clockwise to toggle time zone between GMT & Local.
 
Clock / Timer:
Turn left dial counter clockwise to select clock mode and clockwise to select timer mode.
 
Backlight:
Turn left dial counter clockwise to step back through backlight colours and clockwise to step forward through backlight colours.
     0 = Grey LCD
     1 = Blue
     2 = Orange
     3 = Green
     4 = Plain White
 
Degrees:
Turn left dial counter clockwise to select OAT shown in Celsius and clockwise to select Fahrenheit.
 
Glass Reflection:
Turn left dial clockwise to turn on and counter clockwise to turn off optional glass reflections. This is a global setting so all gauges that have this function will turn on and off in sync.
 
Background Colour:
Left dial will change colour styles to the following
     0 = Grey
     1 = Black Dial Face
     2 = Darker Gauge & Dial Face
     3 = Black & No Gauge GFX
     4 = Grey - Original Design
     5 = Black Dial Face - Original Design
     6 = Darker Gauge & Dial Face - Original Design
 
Brightness:
Turn left Dial clockwise to increase gauge brightness and counter clockwise to decrease gauge brightness. This will adjust the brightness of all gauges at the same time.

Variables:
[S1] SCRIPTED CUSTOM VARIABLE MAPPINGS:
FG_DIGITAL_CLOCK_OAT_VOLTS (Session)
 
FG_DIGITAL_CLOCK_OAT_MENU (Session)
     Menu Item Index (0 to 12)
     0 = Menu Closed
     1 = Version & Info
     2 = Side Buttons
     3 = Time Source
     4 = Time Zone
     5 = Clock/Timer
     6 = Cycle Backlight Colours
     7 = Degrees F or C
     8 = Timer Digits HH:SS or MM:SS
     9 = Glass Reflection
   10 = Background Colour
   11 = Brightness Control
   12 = Panel Lights control
 
FG_DIGITAL_CLOCK_OAT_MENU_ACTIVE (Session)
     If Menu Preview Mode is Active (Off = 0, On = 1)
 
FG_DIGITAL_CLOCK_OAT_FACE (Profile)
     Default Clock Faces (Face 0 to 6)
     0 = Grey LCD
     1 = Red LED
     2 = Orange Backlight LCD
     3 = Blue Backlight with White LCD
     4 = Green Backlight LCD
     5 = Light Blue Backlight LCD
     6 = White Backlight LCD
 
FG_DIGITAL_CLOCK_OAT_TIMER_DIGITS (Profile)
     Mode Timer HH:MM or MM:SS (HH:MM = 0, MM:SS = 1)
 
FG_PROFILE_CLOCK_COLOUR_FORE_ON (Profile)
     Foreground colour of fonts while power is on (default = "#000000")
 
FG_PROFILE_CLOCK_COLOUR_BACK_ON (Profile)
     Background colour of fonts while power is on (default = "#dee2cd")
 
FG_PROFILE_CLOCK_COLOUR_FORE_OFF (Profile)
     Foreground colour of fonts while power is off (default = "#000000")
 
FG_PROFILE_CLOCK_COLOUR_BACK_OFF (Profile)
     Background colour of fonts while power is off (default = "#333333")
 
FG_DIGITAL_CLOCK_OAT_MODE (Profile)
     Mode Timer or Clock (Clock = 0, Timer = 1)
 
 FG_DIGITAL_CLOCK_OAT_TEMP (Profile)
     Toggles between Celsius and Fahrenheit (0 - 1)
     0 = Celsius
     1 = Fahrenheit
 
FG_DIGITAL_CLOCK_OAT_SAVETIME (Profile)
     Stop Watch Paused - Restart Variable (Internal Use Only)
 
FG_DIGITAL_CLOCK_OAT_BUTTONS (Profile)
     Side Buttons (Off = 0, On = 1)
 
FG_DIGITAL_CLOCK_OAT_DIAL (Session)
     Manages rotation of Left Dial
 
FG_DIGITAL_CLOCK_OAT_PAUSE (Profile)
     Timer Stop Start Status (Running = 0, Paused = 1)
 
FG_DIGITAL_CLOCK_FACE (Profile)
     Clock Face (Face 0 to 4)
     0 = Grey LCD
     1 = Blue
     2 = Orange
     3 = Green
     4 = Plain White
 
FG_DIGITAL_CLOCK_OAT_INSTRUCTIONS (Session)
     Instructions Page (Off = 0, On = 1)
 
FG_DIGITAL_CLOCK_OAT_LABELS (Profile)
     Side Button Labels (Off = 0, On = 1)
 
 FG_DIGITAL_CLOCK_OAT_MODE1 (Profile)
     OAT Volts Toggle (OAT = 0, Volts = 1)
 
 FG_DIGITAL_CLOCK_OAT_SWSTART (Profile)
     Stop Watch Start Variable (Internal Use Only)
 
FG_DIGITAL_CLOCK_OAT_TIMEUTC (Profile)
     Time Zone taken from (GMT=0, LOACL = 1)
 
FG_DIGITAL_CLOCK_OAT_TIMESIM (Profile)
     Time taken from (SIM = 0, UTC = 1)
 
SIMCONNECT Vars Used:
AMBIENT TEMPERATURE,Celsius
AMBIENT TEMPERATURE, farenheit
ELECTRICAL MAIN BUS VOLTAGE,Volts
 
 
fipgauges.com GLOBAL VARIABLES:
(not all vars used in every gauge)
 
FG_GLOBAL_DIAL_SPEED (Session)
     Variable used for dial acceleration (Off = 0, On = 1)
 
FG_GLOBAL_GAUGE_BRIGHTNESS (Profile)
     Brightness value of physical FIP's. Affects all physical gauges (20-250)
 
FG_GLOBAL_GAUGE_BRIGHTNESS_MODE (Profile)
     Variable used when editing Global or individual Brightness (0-1)
     0 - Global Brightness
     1 - Inedividual Brightness
FG_GLOBAL_BLANKING_COLOUR (Profile)
     Text Variable used to set blanking plate colour
 
FG_GLOBAL_GLASS (Profile)
     Glass Reflection (Off = 0, On = 1)
 
FG_GLOBAL_HIDE_MENU_LED (Profile)
     Toggle visibility of Mini Menu LED (0 = On, 1 = Off)
 
FG_GLOBAL_JET_COLOUR (Profile)
     Background Colour (0 to 3)
     1 = Grey panel with grey gauge face
     2 = Blue grey panel with grey gauge face
     3 = Dark grey panel with black gauge face
     4 = Dark blue panel with black gauge face.  
 
FG_GLOBAL_JET_BACKGROUND_COLOUR (Profile)
     Background Colour (Black = 0, Blue = 1 )
 
FG_GLOBAL_MIN_VOLTAGE (Profile)
     Minimum voltage before gauge electronics turns off (-1 to 150)
     -1 = Disabled
     0 - 150 = Off Voltage Level
 
FG_GLOBAL_MIN_VOLTAGE_CACHE (Profile)
     Internal Variable - Used to store off voltage value - do not edit
  
FG_GLOBAL_PANEL_LIGHTS (Profile)
     Night Lit Mode (Off = 0, On = 1)
 
FG_GLOBAL_PRESSURE (Profile)
     Shared variable for switching inHg and MB (0 to 1)
     0 = inHg
     1 = Millbars
 
FG_GLOBAL_STYLE (Profile)
  Background Colour (0 to 6)
     0 = Grey
     1 = Black Dial Face
     2 = Darker Gauge & Dial Face
     3 = Black & No Gauge GFX
     4 = Grey - Original Design
     5 = Black Dial Face - Original Design
     6 = Darker Gauge & Dial Face - Original Design
   
FG_GLOBAL_VOLTAGE (Session)
     Internal variable used to read current voltage
 

Release Notes:
1.6.001 - Using New Sidebar Button and Labels Code (4 display options now also) - blank sidebar custom colour
1.6.000
     - 1) SPAD.neXt 0.9.15 Compatibility (Convert "PRESS" to "PRESSSHORT") Fixes short and long press both firing on long press.
     - 2) New gauge brightness code using SPAD brightness variables.
     - 3) Can control global or individual gauge brightness in gauge (Profile saved settings)
     - 4) Better use of button lights
1.5.002 - SPAD.neXt 0.9.13 Compatibility (Author ID)
1.5.001 - Minor syntax fixed in code
1.5.000 - New Meun System
1.4.002 - [LongPress S1] Added Toggle for Timer in HH:MM or MM:SS
1.4.001 - Added ºC or ºF to OAT label depending on the selected mode for confirmation
1.4.000 - New Custom Virtual Power supports ALL aircraft volt variables - See https://fipgauges.com/customfeatures.php
1.3.003 - Added sidebar blanking plate option
1.3.002 - Fixed UT & LT Underscore being back to front
1.3.001 - Virtual Power Warning added to Menu
1.3.000 - Added New Gauge Design and Panel Lighting control in Mini Menu
1.2.002 - Support for NEW 4 colour hue panel lights.
1.2.001 - Tweaked voltage monitoring to better support MSFS2020. Added Monitoring for Battery Bus
1.2.000 - SPAD 0.9.7.x - Custom Text Foreground and Background Colours
1.1.003 - Automatic Dial Acceleration added to timer adjustment
1.1.002 - Added Brightness Control to Mini Menu
1.1.001 - Fixed voltage spiking on A2A aircraft
1.1.000 - Panel Lights now controlled by local variable (FG_GLOBAL_PANEL_LIGHTS) 0=Off 1=On
1.0.002 - Seconds bar shown on timer. Timer Start and Stop function added [S6] Toggle start Stop. Reset is now [S6 long press]
1.0.001 - Graphics bugs when no voltage present.
1.0.000 - First Public release.

Please report any bugs or feature requests via our discord channel


Document Published 12/02/2024

Copyright fipgauges.com 12/02/2024