GAUGE: Fuel Gauge
Gauge v2.6.001 - Current Version 12th Feb 2024

Features:
1) Displays Fuel level in % for 12 Tanks
2) Tanks Left - Main, Tip & Aux
3) Tanks Right - Main, Tip & Aux
4) Tanks Centre Tanks - 1, 2 & 3
5) Selected Tank
6) Fuel Flow 1-4 Engines
7) Warning Lights when fuel is Low (All tanks)
8) Variable Fuel Flow Ranges 40 - 400 - 4000
9) Lighting changes with panel lights
10) Lighting changes with panel lights
11) Optional Glass Reflections
12) Brightness Control (Physical FIP)

Aircraft Compatibility:
Simulator: Fully Compatible
3rd Party: Fully Compatible
Please report any 3rd Party incompatibility via our discord channel

Buttons & Dials Summary:
[S1] Pick Flow Scale:
[S2] Toggle Percent/Gallons:
[S6] Toggle Tank Displayed:
[L Dial] Menu Value Down/Up:
[R Dial] Menu Left/Right:

About Fuel Gauge:
Every aircraft needs a fuel gauge! and this gauges monitors all twelve of the current SIMCONNECT tanks

The Main Gauge:
Fuel quantity is displayed on main gauge as a percentage of the selected tanks. There are 6 pairs of tank selections that can be toggled using the [S6] button.
     1 = Left and Right
     2 = Aux Left and Right
     3 = Tip Left and right
     4 = Center 1 and Center 2
     5 = Center 3 and Selected Quantity
     6 = External 1 and External 2

The Sidebar:
This shows the fuel flow in pounds per hour. There are three different scales which should cover aircraft fuel flow from Cessna to a 747.
     x1 = Low
   x10 = Medium
 x100 = High
 
Press [S1] to skip through the three available scales.
 
If the blanking plate is used instead of the sidebar, then colour of the plate can now be changed by editing variable [FG_GLOBAL_BLANKING_COLOUR] in SPAD.neXt data monitor.

Buttons & Dials Details:
[S1] Pick Flow Scale:
Pressing [S1] will step through 3 different fuel flow ranges.
     1 = Low
   10 = Medium
 100 = High
 
[S2] Toggle Percent/Gallons:
Pressing [S2] Will toggle Percentage to Gallons (Calculated)
 
[S6] Toggle Tank Displayed:
Pressing [S6] will step through 6 different pairs of fuel tanks and will display fuel % if the aircraft has the selected tanks.
     1 = Left and Right
     2 = Aux Left and Right
     3 = Tip Left and right
     4 = Center 1 and Center 2
     5 = Center 3 and Selected Quantity
     6 = External 1 and External 2
 
[L Dial] Menu value down/up:
When Mini Menu is open use [L Dial] to change the value of the selected menu option.
 
[R Dial] Menu Function Previous/Next:
Used to activate the Mini Menu and scroll between the various menu options.
 
 

The Mini Menu:
Version & Info:
Turn left dial clockwise to turn on and counter clockwise to turn off current version number and other useful links.
 
Side Buttons:
Turn left dial clockwise to turn on and counter clockwise to turn off side buttons.
 
Fuel Flow Scale:
This option allows you to change the scaling of the Pounds Per Hour indicators in the sidebar.
 
Fuel Tank:
This toggles output between the various available fuel tanks.
     0 = Left and Right
     1 = Aux Left and Right
     2 = Tip Left and right
     3 = Center 1 and Center 2
     4 = Center 3 and Selected Quantity
     5 = External 1 and External 2
 
Glass Reflection:
Turn left dial clockwise to turn on and counter clockwise to turn off optional glass reflections. This is a global setting so all gauges that have this function will turn on and off.
 
Background Colour:
Left dial will change colour styles to the following
     0 = Grey
     1 = Black Dial Face
     2 = Darker Gauge & Dial Face
     3 = Black & No Gauge GFX
     4 = Grey - Original Design
     5 = Black Dial Face - Original Design
     6 = Darker Gauge & Dial Face - Original Design
 
Brightness:
Turn left Dial clockwise to increase gauge brightness and counter clockwise to decrease gauge brightness. This will adjust the brightness of all gauges at the same time.
 
 

Variables:
FG_FUEL_MENU (Session)
     Menu Item Index (0 to 8)
     0 = Menu Closed
     1 = Version & Info
     2 = Side Buttons
     3 = Fuel Flow Scale
     4 = Fuel Tank
     5 = Glass Reflection
     6 = Background Colour
     7 = Brightness Control
     8 = Panel Lights Control
 
FG_FUEL_MENU_ACTIVE (Session)
     If Menu Preview Mode is Active (Off = 0, On = 1)
 
FG_FUEL_INSTRUCTIONS (Session)
     Instructions Page (Off = 0, On = 1)
 
FG_FUEL_BUTTONS (Profile)
     Side Buttons (Off = 0, On = 1)
 
FG_FUEL_LABELS (Profile)
     Side Button Labels (Off = 0, On = 1)
 
FG_FUEL_MAIN_AUX_SWITCH (Profile)
Tank selection for display on main gauge (0 - 5)
     0 = Left and Right
     1 = Aux Left and Right
     2 = Tip Left and right
     3 = Center 1 and Center 2
     4 = Center 3 and Selected Quantity
     5 = External 1 and External 2
 
FG_FUEL_FLOWRATE (Profile)
     Selected Sidebar flow rate (1, 10 or 100)
     1 = Low
   10 = Medium
 100 = High
 
SIMCONNECT Vars Used:
NUMBER OF ENGINES,number
ENG FUEL FLOW GPH:1,Gallons per hour
ENG FUEL FLOW GPH:2,Gallons per hour
ENG FUEL FLOW GPH:3,Gallons per hour
ENG FUEL FLOW GPH:4,Gallons per hour
FUEL TANK LEFT MAIN LEVEL,PERCENT
FUEL TANK RIGHT MAIN LEVEL,PERCENT
FUEL TANK LEFT AUX LEVEL,PERCENT
FUEL TANK RIGHT AUX LEVEL,PERCENT
FUEL TANK LEFT TIP LEVEL,PERCENT
FUEL TANK RIGHT TIP LEVEL,PERCENT
FUEL TANK CENTER LEVEL,PERCENT
FUEL TANK CENTER2 LEVEL,PERCENT
FUEL TANK CENTER3 LEVEL,PERCENT
FUEL SELECTED QUANTITY PERCENT,Percent
FUEL TANK EXTERNAL1 LEVEL,PERCENT
FUEL TANK EXTERNAL2 LEVEL,PERCENT
 
fipgauges.com GLOBAL VARIABLES:
(not all vars used in every gauge)
 
FG_GLOBAL_DIAL_SPEED (Session)
     Variable used for dial acceleration (Off = 0, On = 1)
 
FG_GLOBAL_GAUGE_BRIGHTNESS (Profile)
     Brightness value of physical FIP's. Affects all physical gauges (20-250)
 
FG_GLOBAL_GAUGE_BRIGHTNESS_MODE (Profile)
     Variable used when editing Global or individual Brightness (0-1)
     0 - Global Brightness
     1 - Individual Brightness
  
FG_GLOBAL_BLANKING_COLOUR (Profile)
     Text Variable used to set blanking plate colour
 
FG_GLOBAL_GLASS (Profile)
     Glass Reflection (Off = 0, On = 1)
 
FG_GLOBAL_HIDE_MENU_LED (Profile)
     Toggle visibility of Mini Menu LED (0 = On, 1 = Off)
 
FG_GLOBAL_JET_COLOUR (Profile)
     Background Colour (0 to 3)
     1 = Grey panel with grey gauge face
     2 = Blue grey panel with grey gauge face
     3 = Dark grey panel with black gauge face
     4 = Dark blue panel with black gauge face.  
 
FG_GLOBAL_JET_BACKGROUND_COLOUR (Profile)
     Background Colour (Black = 0, Blue = 1 )
 
FG_GLOBAL_MIN_VOLTAGE (Profile)
     Minimum voltage before gauge electronics turns off (-1 to 150)
     -1 = Disabled
     0 - 150 = Off Voltage Level
 
FG_GLOBAL_MIN_VOLTAGE_CACHE (Profile)
     Internal Variable - Used to store off voltage value - do not edit
  
FG_GLOBAL_PANEL_LIGHTS (Profile)
     Night Lit Mode (Off = 0, On = 1)
 
FG_GLOBAL_PRESSURE (Profile)
     Shared variable for switching inHg and MB (0 to 1)
     0 = inHg
     1 = Millbars
 
FG_GLOBAL_STYLE (Profile)
  Background Colour (0 to 6)
     0 = Grey
     1 = Black Dial Face
     2 = Darker Gauge & Dial Face
     3 = Black & No Gauge GFX
     4 = Grey - Original Design
     5 = Black Dial Face - Original Design
     6 = Darker Gauge & Dial Face - Original Design
   
FG_GLOBAL_VOLTAGE (Session)
     Internal variable used to read current voltage
 

Release Notes:
2.6.001 - Using New Sidebar Button and Labels Code (4 display options now also) - blank sidebar custom colour
2.6.000
     - 1) SPAD.neXt 0.9.15 Compatibility (Convert "PRESS" to "PRESSSHORT") Fixes short and long press both firing on long press.
     - 2) New gauge brightness code using SPAD brightness variables.
     - 3) Can control global or individual gauge brightness in gauge (Profile saved settings)
     - 4) Better use of button lights
2.5.001 - SPAD.neXt 0.9.13 Compatibility (Author ID)
2.5.000 - New Menu System
2.4.001 - Fixed background colour/style not changing
2.4.000 - New Custom Virtual Power supports ALL aircraft volt variables - See https://fipgauges.com/customfeatures.php
2.3.003 - Added sidebar blanking plate option
2.3.002 - Added display fuel in Gallons [S2] toggle also not auto skips not applicable tanks.
2.3.001 - Virtual Power Warning added to Menu
2.3.000 - Added New Gauge Design and Panel Lighting control in Mini Menu
2.2.004 - Support for NEW 4 colour hue panel lights.
2.2.003 - Tweaked voltage monitoring to better support MSFS2020. Added Monitoring for Battery Bus
2.2.002 - SPAD.neXt 0.9.7.x Variable Scope Compatibility
2.2.001 - Added Brightness Control to Mini Menu
2.2.000 - Panel Lights now controlled by local variable (FG_GLOBAL_PANEL_LIGHTS) 0=Off 1=On
2.1.001 - Resized Text to become compliant with SPAD.neXt scaling changes
2.0.000 - New colour schemes available in mini menu.
1.6.000 - Improved graphics with shadows and transparency, Optional glass reflections.
1.5 000 - Added Tanks: Centre 3, External 1 & 2 and Sim Selected
1.4.001 - Added turn off powered items when no voltage
1.4.000 - New Menu Control
1.3.000 - Multiple Tank switch
1.2.000 - Multiple Engine Fuel Flows
1.1.000 - Public release
1.0.000 - Initial Build
 

Please report any bugs or feature requests via our discord channel


Document Published 29/03/2024

Copyright fipgauges.com 29/03/2024