GAUGE: Fuel Flow
Gauge v2.7.001 - Current Version 12th Feb 2024

Features:
This is for Prop and Turbo Prop aircraft not jets.
Make sure your aircraft consumption falls within supported ranges.
 
1) Analogue Fuel indicator ENG 1-4 (Switched)
2) Digital Fuel Flow displays ENG 1-4
3) Switch between PPH and GPH (Lbs/Gallons)
4) 10 range face plates (Lbs and Gallons)
     Lbs 0-80 ph
     Lbs 0-120 ph
     Lbs 0-160 ph
     Lbs 0-800 ph
     Lbs 0-1200 ph
     Lbs 0-1600 ph
     Gallons 0-16 ph
     Gallons 0-32 ph
     Gallons 0-64 ph    
     Gallons 0-128 ph
5) Optional Glass Reflection
6) Brightness Control (Physical FIP)

Aircraft Compatibility:
Simulator: Fully Compatible
3rd Party: Fully Compatible
Please report any 3rd Party incompatibility via our discord channel

Buttons & Dials Summary:
[S1] Menu Preview Function:
[S4] PPH x10/x100:
[S5] Toggle Gauge Scales:
[S6] Change Displayed Engine:
[L Dial] Menu Value Down/Up:
[R Dial] Menu Left/Right:

About Fuel Flow:
The fuel flow gauge allows you to monitor how much fuel you are burning. You can output this in either Pounds or Gallons and each has two different ranges  (Lbs 0-8, Lbs 0-16, Gallons 0-16, Gallons 0-64). This gauge is not designed for high fuel burn and or Jets.

The Main Gauge:
N/A

The Sidebar:
Sidebar has fuel flow in digital output for all available engines.
 
If the blanking plate is used instead of the sidebar, then colour of the plate can now be changed by editing variable [FG_GLOBAL_BLANKING_COLOUR] in SPAD.neXt data monitor.

Buttons & Dials Details:
[S1] Mini Menu Preview toggle
Press [S1] while in menu to exit or toggle preview mode on/off
 
[S5] Toggle Gauge Scales:
Press to select/toggle between four different gauge scales
     Lbs 0-8
     Lbs 0-16
     Gallons 0-16
     Gallons 0-64
 
[S6]  Engine Number Selection:
Press to toggle engine output through available engines.
 
[L Dial] Menu value down/up:
When Mini Menu is open use [L Dial] to change the value of the selected menu option.
 
[R Dial] Menu Function Previous/Next:
Used to activate the Mini Menu and scroll between the various menu options.
 
 

The Mini Menu:
Version & Info:
Turn left dial clockwise to turn on and counter clockwise to turn off current version number and other useful links.
 
Side Buttons:
Turn left dial clockwise to turn on and counter clockwise to turn off side buttons.
 
Scale Menu:
select between four different gauge scales
     Lbs 0-8
     Lbs 0-16
     Gallons 0-16
     Gallons 0-64
 
ENGINE NUMBER:
Select which engine to output data from. If displaying out put for engine that doesn't exist then the output will be "0"
 
Glass Reflection:
Turn left dial clockwise to turn on and counter clockwise to turn off optional glass reflections. This is a global setting so all gauges that have this function will turn on and off.
 
Background Colour:
Left dial will change colour styles to the following
     0 = Grey
     1 = Black Dial Face
     2 = Darker Gauge & Dial Face
     3 = Black & No Gauge GFX
     4 = Grey - Original Design
     5 = Black Dial Face - Original Design
     6 = Darker Gauge & Dial Face - Original Design
 
Brightness:
Turn left Dial clockwise to increase gauge brightness and counter clockwise to decrease gauge brightness. This will adjust the brightness of all gauges at the same time.
 

Variables:
FG_FUELFLOW_INSTRUCTIONS (Session)
     Instructions Page (Off = 0, On = 1)
 
FG_FUELFLOW_BUTTONS (Profile)
     Side Buttons (Off = 0, On = 1)
 
FG_FUELFLOW_LABELS (Profile)
     Side Button Labels (Off = 0, On = 1)
 
FG_FUELFLOW_MENU (Session)
     Menu Item Index (0 to 10)
     0 = Menu Closed
     1 = Version & Info
     2 = Side Buttons
     3 = Scale Menu
     4 = PPH Toggle x10 or x100
     5 = Engine Number
     6 = Glass Reflection
     7 = Bacground colour
     8 = LCD - LED - Custom Colours
     9 = Brightness Control
   10 = Panel Lights control
 
FG_FUELFLOW_MENU_ACTIVE (Session)
     If Menu Preview Mode is Active (Off = 0, On = 1)
 
FG_FUELFLOW_ENGINE_NUMBER (Device)
     Engine number selected for Output (1 - 4)
 
FG_FUELFLOW_FACE (Profile)
     Gauge Face Style Selected (0 - 3)
     0 = Lbs 0-8
     1 = Lbs 0-12
     2 = Lbs 0-16
     3 = Gallons 0-16
     4 = Gallons 0-32
     5 = Gallons 0-64
 
FG_FUELFLOW_PPH_TIMES (Profile)
     Lbs per Hour multiplier (must = 1 or 10 or 100 or 1000)
 
FG_PROFILE_LED_COLOUR_FORE_ON (Profile)
     Foreground colour of fonts while power is on (default = "#dd0000")
 
FG_PROFILE_LED_COLOUR_BACK_ON (Profile)
     Background colour of fonts while power is on (default = "#000000")
 
FG_PROFILE_LED_COLOUR_FORE_OFF (Profile)
     Foreground colour of fonts while power is off (default = "#000000")
 
FG_PROFILE_LED_COLOUR_BACK_OFF (Profile)
     Background colour of fonts while power is off (default = "#000000")
 
FG_PROFILE_LED_COLOUR_FORE_ON_CUSTOM (Profile)
     Foreground colour of fonts while power is on (default = "#00DD00")
 
FG_PROFILE_LED_COLOUR_BACK_ON_CUSTOM (Profile)
     Background colour of fonts while power is on (default = "TRANSPARENT")
 
FG_PROFILE_LED_COLOUR_FORE_OFF_CUSTOM (Profile)
     Foreground colour of fonts while power is off (default = "#001100")
 
FG_PROFILE_LED_COLOUR_BACK_OFF_CUSTOM (Profile)
     Background colour of fonts while power is off (default = "TRANSPARENT")
 
FG_VARIABLES_LEDCOLOUR (Profile)
     Side panel LED Style Index (1 - 3)
     1 = LED Style
     2 = LCD Style (Default)
     3 = Custom
  
SIMCONNECT Vars Used:
ENG FUEL FLOW PPH:1, POUNDS per hour
ENG FUEL FLOW GPH:1, Gallons per hour
ENG FUEL FLOW PPH:2, POUNDS per hour
ENG FUEL FLOW GPH:2, Gallons per hour
ENG FUEL FLOW PPH:3, POUNDS per hour
ENG FUEL FLOW GPH:3, Gallons per hour
ENG FUEL FLOW PPH:4, POUNDS per hour
ENG FUEL FLOW GPH:4, Gallons per hour
NUMBER OF ENGINES, Number
 
fipgauges.com GLOBAL VARIABLES:
(not all vars used in every gauge)
 
FG_GLOBAL_DIAL_SPEED (Session)
     Variable used for dial acceleration (Off = 0, On = 1)
 
FG_GLOBAL_GAUGE_BRIGHTNESS (Profile)
     Brightness value of physical FIP's. Affects all physical gauges (20-250)
 
FG_GLOBAL_GAUGE_BRIGHTNESS_MODE (Profile)
     Variable used when editing Global or individual Brightness (0-1)
     0 - Global Brightness
     1 - Inedividual Brightness
FG_GLOBAL_BLANKING_COLOUR (Profile)
     Text Variable used to set blanking plate colour
 
FG_GLOBAL_GLASS (Profile)
     Glass Reflection (Off = 0, On = 1)
 
FG_GLOBAL_HIDE_MENU_LED (Profile)
     Toggle visibility of Mini Menu LED (0 = On, 1 = Off)
 
FG_GLOBAL_JET_COLOUR (Profile)
     Background Colour (0 to 3)
     1 = Grey panel with grey gauge face
     2 = Blue grey panel with grey gauge face
     3 = Dark grey panel with black gauge face
     4 = Dark blue panel with black gauge face.  
 
FG_GLOBAL_JET_BACKGROUND_COLOUR (Profile)
     Background Colour (Black = 0, Blue = 1 )
 
FG_GLOBAL_MIN_VOLTAGE (Profile)
     Minimum voltage before gauge electronics turns off (-1 to 150)
     -1 = Disabled
     0 - 150 = Off Voltage Level
 
FG_GLOBAL_MIN_VOLTAGE_CACHE (Profile)
     Internal Variable - Used to store off voltage value - do not edit
  
FG_GLOBAL_PANEL_LIGHTS (Profile)
     Night Lit Mode (Off = 0, On = 1)
 
FG_GLOBAL_PRESSURE (Profile)
     Shared variable for switching inHg and MB (0 to 1)
     0 = inHg
     1 = Millbars
 
FG_GLOBAL_STYLE (Profile)
  Background Colour (0 to 6)
     0 = Grey
     1 = Black Dial Face
     2 = Darker Gauge & Dial Face
     3 = Black & No Gauge GFX
     4 = Grey - Original Design
     5 = Black Dial Face - Original Design
     6 = Darker Gauge & Dial Face - Original Design
   
FG_GLOBAL_VOLTAGE (Session)
     Internal variable used to read current voltage
 

Release Notes:
2.7.001 - Using New Sidebar Button and Labels Code (4 display options now also) - blank sidebar custom colour
2.7.000
     - 1) SPAD.neXt 0.9.15 Compatibility (Convert "PRESS" to "PRESSSHORT") Fixes short and long press both firing on long press.
     - 2) New gauge brightness code using SPAD brightness variables.
     - 3) Can control global or individual gauge brightness in gauge (Profile saved settings)
     - 4) Better use of button lights
2.6.003 - SPAD.neXt 0.9.13 Compatibility (Author ID)
2.6.002 - Fixed wrong label on 0-128 Gallons
2.6.001 - Added 0 - 12 LBS and 0 - 32 + 0 - 128 GPH Ranges. Added PPH toggle for x100 or x10. Number of ranges from 4 to 10. Digital values now actual instead of copy of analogue numbers.
2.6.000 - New Menu System
2.5.000 - New Custom Virtual Power supports ALL aircraft volt variables - See https://fipgauges.com/customfeatures.php
2.4.002 - Added sidebar blanking plate option
2.4.001 - Virtual Power Warning added to Menu
2.4.000 - Added New Gauge Design and Panel Lighting control in Mini Menu
2.3.002 - Support for NEW 4 colour hue panel lights.
2.3.001 - Tweaked voltage monitoring to better support MSFS2020. Added Monitoring for Battery Bus
2.3.000 - SPAD.neXt 0.9.7.x Compatibility, Custom Display Colours
2.2.002 - Added Engine number control to Mini Menu. New clearer scale sub menu in Mini Menu.
2.2.001 - Added Brightness Control to Mini Menu
2.2.000 - Panel Lights now controlled by local variable (FG_GLOBAL_PANEL_LIGHTS) 0=Off 1=On
2.1.001 - Resized Text to become compliant with SPAD.neXt scaling changes
2.0.000 - New colour schemes available in mini menu.
1.0.000 - Public Release

Please report any bugs or feature requests via our discord channel


Document Published 12/02/2024

Copyright fipgauges.com 12/02/2024