GAUGE: Panel Displays
Gauge v1.4.000 - Current Version 20th Feb 2024

Features:
1) Select from 10 Outputs in two windows
2) Left Dial changes displayed Function
3) Right Dial Changes function Value
4) [S2] & [S5] Select "Active Window"
5) Optional Glass Reflection
6) Brightness Control (Physical FIP)
 
ALT, VS, IAS, HDG, CRS, Com&Nav1, Com&Nav2, ADF, DME, XPDR
100 different combinations.
 
Click on Reference Guide for instructions on how to operate this gauge.
  
While similar to my other Radio and Multipanel gauges, this gauges has simplified displays, combines Radio and Multipanel displays. Values can be changed in gauge also.
 
* COM:3 not supported

Aircraft Compatibility:
Simulator: Fully Compatible
3rd Party: Fully Compatible
Please report any 3rd Party incompatibility via our discord channel

Buttons & Dials Summary:
[S1] Toggle Frequencies / Hold for Mini Menu:
[S2] Top Window Active / Cursor Next Value:
[S3] Toggle Frequencies:
[S4] Toggle Frequencies:
[S5] Bottom Window Active / Cursor Next Value:
[S6] Toggle Frequencies:
[L Dial] Previous Function/Next Function:
[R Dial] Value Down/Up:

About Panel Displays:
To Activate the gauge menu Press and HOLD [S1]
 
Press [S2] To "active" Top Window. [S2] will light to indicate active window.
Press [S5] to "active" Bottom Window. [S5] will light to indicate active window.
 
Turn [Left Dial] to change "active" window's function. Each window can show 1 of 10 different Panel Display functions.
 
When Radio functions are displayed in any window, press the [S] button left of the frequency you want to swap, so..
In Top Window Press [S1] to toggle COM frequencies and [S3] to toggle NAV frequencies.
In Bottom Window Press [S4] to toggle COM frequencies and [S6] to toggle NAV frequencies.
 
Turn [Right Dial] to change the value of the "active" window's current function. When Radios frequencies are displayed you will need to toggle the value you want to edit by RE-pressing the already lit window activation button ([S2] if Top window is "active" and [S5] if bottom window is "active", this will cycle between the four changeable value and "value indicator off".
 
Transponder:
When Transponder is selected in the top window:
[S1] = Squawk 1200
[S3] = Emergency 7700
 
When Transponder is selected in the bottom window:
[S4] = Squawk 1200
[S6] = Emergency 7700
 
You can change the codes by editing the XPDR Emergency and XPDR Squawk values in the button events for [S1][S3][S4][S6]d XPDR Squawk values in the button events for [S1][S3][S4][S6]

The Mini Menu:
(Hold [S1] to Activate and Deactivate)
 
Version & Info:
Turn left dial clockwise to turn on and counter clockwise to turn off current version number and other useful links.
  
Glass Reflection:
Turn left dial clockwise to turn on and counter clockwise to turn off optional glass reflections. This is a global setting so all gauges that have this function will turn on and off in sync.

Variables:
FG_PANELDISPLAYS_MENU (Session)
     Menu Item Index (0 to 4)
     0 = Menu Closed
     1 = Version & Info
     2 = Glass Reflection
     3 = Colours - Custom
     4 = Brightness Control
 
FG_PANELDISPLAYS_INSTRUCTIONS (Session)
     Instructions Page (Off = 0, On = 1)
 
FG_RADIO2_COLOUR_INDEX (Profile)
     Side panel LED Style Index (0 - 0)
     1 = LED Style Red
     2 = LCD Style
     3 = LED Style Green
     4 = LCD Style Black with Green Backlight
     5 = LED Style White with Blue Backlight
     6 = LCD Style Black with Green Backlight
     7 = LCD Style Black with Blue Backlight
     8 = Custom Colours (See Below)
 
FG_PROFILE_RADIO_COLOUR_FORE_ON (Profile)
     Foreground colour of fonts while power is on (default = "#ff0000")
 
FG_PROFILE_RADIO_COLOUR_BACK_ON (Profile)
     Background colour of fonts while power is on (default = "#000000")
 
FG_PROFILE_RADIO_COLOUR_FORE_OFF (Profile)
     Foreground colour of fonts while power is off (default = "#220000")
 
FG_PROFILE_RADIO_COLOUR_BACK_OFF (Profile)
     Background colour of fonts while power is off (default = "#000000")
 
FG_PROFILE_RADIO_COLOUR_FORE_ON_CUSTOM (Profile)
     Foreground colour of fonts while power is on (default = "#00DD00")
 
FG_PROFILE_RADIO_COLOUR_BACK_ON_CUSTOM (Profile)
     Background colour of fonts while power is on (default = "FFFFFF")
 
FG_PROFILE_RADIO_COLOUR_FORE_OFF_CUSTOM (Profile)
     Foreground colour of fonts while power is off (default = "#000000")
 
FG_PROFILE_RADIO_COLOUR_BACK_OFF_CUSTOM (Profile)
     Background colour of fonts while power is off (default = "333333")
 
SIMCONNECT Vars Used:
AUTOPILOT ALTITUDE LOCK VAR,feet
AUTOPILOT VERTICAL HOLD VAR,FEET PER MINUTE
AUTOPILOT AIRSPEED HOLD VAR,knots
Autopilot heading lock dir,degrees
NAV obs:1,degrees
COM ACTIVE FREQUENCY:1,MHz
COM STANDBY FREQUENCY:1,MHz
NAV ACTIVE FREQUENCY:1,MHz
NAV STANDBY FREQUENCY:1,MHz
COM ACTIVE FREQUENCY:2,MHz
COM STANDBY FREQUENCY:2,MHz
NAV ACTIVE FREQUENCY:2,MHz
NAV STANDBY FREQUENCY:2,MHz
ADF ACTIVE FREQUENCY:1,KHz
NAV DME:1, Nautical miles
NAV DME:2, Nautical miles
 
fipgauges.com GLOBAL VARIABLES:
(not all vars used in every gauge)
 
FG_GLOBAL_DIAL_SPEED (Session)
     Variable used for dial acceleration (Off = 0, On = 1)
 
FG_GLOBAL_GAUGE_BRIGHTNESS (Profile)
     Brightness value of physical FIP's. Affects all physical gauges (20-250)
 
FG_GLOBAL_GAUGE_BRIGHTNESS_MODE (Profile)
     Variable used when editing Global or individual Brightness (0-1)
     0 - Global Brightness
     1 - Individual Brightness
 
FG_GLOBAL_GLASS (Profile)
     Glass Reflection (Off = 0, On = 1)
 
FG_GLOBAL_HIDE_MENU_LED (Profile)
     Toggle visibility of Mini Menu LED (0 = On, 1 = Off)
 
FG_GLOBAL_JET_COLOUR (Profile)
     Background Colour (0 to 3)
     1 = Grey panel with grey gauge face
     2 = Blue grey panel with grey gauge face
     3 = Dark grey panel with black gauge face
     4 = Dark blue panel with black gauge face.  
 
FG_GLOBAL_JET_BACKGROUND_COLOUR (Profile)
     Background Colour (Black = 0, Blue = 1 )
 
FG_GLOBAL_MIN_VOLTAGE (Profile)
     Minimum voltage before gauge electronics turns off (-1 to 150)
     -1 = Disabled
     0 - 150 = Off Voltage Level
 
FG_GLOBAL_MIN_VOLTAGE_CACHE (Profile)
     Internal Variable - Used to store off voltage value - do not edit
  
FG_GLOBAL_PANEL_LIGHTS (Profile)
     Night Lit Mode (Off = 0, On = 1)
 
FG_GLOBAL_PRESSURE (Profile)
     Shared variable for switching inHg and MB (0 to 1)
     0 = inHg
     1 = Millbars
 
FG_GLOBAL_STYLE (Profile)
  Background Colour (0 to 6)
     0 = Grey
     1 = Black Dial Face
     2 = Darker Gauge & Dial Face
     3 = Black & No Gauge GFX
     4 = Grey - Original Design
     5 = Black Dial Face - Original Design
     6 = Darker Gauge & Dial Face - Original Design
   
FG_GLOBAL_VOLTAGE (Session)
     Internal variable used to read current voltage
 

Release Notes:
1.4.000
     1) SPAD.neXt 0.9.15 Compatibility (Convert "PRESS" to "PRESSSHORT") Fixes short and long press both firing on long press.
     2) Menu system upgraded
     3) New gauge brightness code using SPAD brightness variables.
     4) Can control global or individual gauge brightness in gauge (Profile saved settings)
     5) Better use of button lights
1.3.007 - Fixed 4th digit on XPNDR only decrementing and not incrementing
1.3.006 - New Custom Virtual Power supports ALL aircraft volt variables - See https://fipgauges.com/customfeatures.php
1.3.005 - SPAD.neXt detected code format errors fixed
1.3.004 - Virtual Power Warning added to Menu
1.3.003 - Multi FIP support, Different function selections across different FIPs
1.3.002 - Support for NEW 4 colour hue panel lights.
1.3.001 - Tweaked voltage monitoring to better support MSFS2020. Added Monitoring for Battery Bus
1.3.000 - SPAD.neXt 0.9.7.x Compatible. Custom Radio Frequency Colours.
1.2.002 - Added Transponder Squawk and Emergency codes.
1.2.001 - Added Brightness Control to Menu.
1.2.000 - Panel Lights now controlled by local variable (FG_GLOBAL_PANEL_LIGHTS) 0=Off 1=On
1.1.000 - Resized Text to become compliant with SPAD.neXt scaling changes
1.0.000 - Public Release

Please report any bugs or feature requests via our discord channel


Document Published 20/02/2024

Copyright fipgauges.com 20/02/2024